  • Standard Vicat Apparatus Vicat Test Set Vicat Needle ...

    Standard Vicat Apparatus Vicat Test Set Vicat Needle Apparatus And Setting Time , Find Complete Details about Standard Vicat Apparatus Vicat Test Set Vicat Needle Apparatus And Setting Time,Vicat Test,Consistency Vicat,Vicat Apparatus from Testing Equipment Supplier or Manufacturer-Hangzhou Civit Instrument Equipment Co., Ltd.

    Get Price
  • Cement Standard Vicat Test Set,Vicat Needle Apparatus ...

    Vicat test set. Used for determination of setting time and consistency of cement by Vicat Method. The apparatus consists of a metal frame with a sliding rod. An adjustable indicator moves over a graduated scale. The needle or plunger is attached to the bottom end of the rod to make up the test weight of 300g.

    Get Price
  • Stwky-1 Standard Vicat Apparatus - China Vicat Apparatus ...

    STWKY-1 Standard Vicat apparatus Meet Standards: GB/T1346 , ASTM C187, ISO9597 standards. I. Application Used for determination of setting time and consistency of cement by Vicat Method.The apparatus consists of a metal frame with a sliding rod. An adjustable indicator moves over a graduated scale.

    Get Price
  • Vicat Apparatus, Initial Final Setting Time | Cement ...

    Used for determination of setting time and consistency of cement by Vicat Method.The apparatus consists of a metal frame with a sliding rod. An adjustable indicator moves over a graduated scale. The needle or plunger is attached to the bottom end of the rod to make up the test weight of 300g.

    Get Price
  • Cement Vicat Test Set,Vicat Needle Apparatus,Vicat ...

    Used for determination of setting time and consistency of cement by Vicat Method. The apparatus consists of a metal frame with a sliding rod. An adjustable indicator moves over a graduated scale. The needle or plunger is attached to the bottom end of the rod to make up the test weight of 300g.

    Get Price
  • China Vicat Needle Apparatus for Cement Testing - China ...

    The Vicat Test Apparatus is used to determine the amount of water required to produce a cement paste of standard consistency and the setting time. The frame is supplied complete with a 300 g consistency plunger (dia. 10 mm). The measurement of the movement is given by an indicator which moves along a scale graduated in millimetres.

    Get Price
  • Vicat Test Apparatus - TESTMAK

    Initial and Final Setting Time of Cement Vicat Test Set Used for determination of setting time and consistency of Cement by Vicat Method. The apparatus consists of a metal Frame with a sliding rod. An adjustable indicator moves over A graduated scale. The needle or plunger is attached to the Bottom end of the rod to make up the test weight of 300g.

    Get Price
  • Initial and Final Setting Time of Cement Vicat Test Set

    2020-8-27 · Vicat Apparatus is Used For:- Vicat apparatus is generally used to determine the required quantity of water to produce a cement paste of normal or standard consistency. It is also used in the tests for initial setting time of cement or concrete and final setting time of cement …

    Get Price
  • What is Vicat Apparatus? Vicat Apparatus is Used for ...

    2020-10-21 · What is Vicat’s Apparatus? Vicat’s Apparatus is extensively used to take out the consistency of cement, initial setting time and final setting time. Vicat’s apparatus has an arrangement that consists of a Vicat plunger (10 mm in diameter), Vicat needles, Vicat mould, gauging trowel, measuring jar (200ml capacity), weighing balance, stopwatch, weight box, glass …

    Get Price
  • Cement Standard Vicat Test Set,Vicat Needle Apparatus ...

    Vicat test set. Used for determination of setting time and consistency of cement by Vicat Method. The apparatus consists of a metal frame with a sliding rod. An adjustable indicator moves over a graduated scale. The needle or plunger is attached to the bottom end of the rod to make up the test weight of 300g.

    Get Price
  • Standard Vicat Apparatus | Controls Group

    The Vicat frame consists essentially of a metal stand with a sliding rod. An adjustable indicator moves over a graduated scale. The needle or plunger is attached to the bottom end of the rod to make up the test weight of 300 g. The frame 63-L0028/1 is supplied without accessories, which have to be ordered separately depending on the requirement.

    Get Price
  • Vicat Apparatus | ELE International

    The Vicat Apparatus is designed for determining the normal consistency, standard consistency and time of setting of cement and lime in accordance with ASTM and AASHTO specifications. The apparatus consists of a frame bearing a movable plunger of 300 grams weight. The Plunger is 10 mm diameter at one end and is fitted with a removable 1 mm ...

    Get Price
  • China Vicat Apparatus, China Vicat Apparatus

    China Vicat Apparatus - Select 2021 high quality China Vicat Apparatus products in best price from certified Chinese Impact Test Apparatus manufacturers, Water Distillation Apparatus suppliers, wholesalers and factory on Made-in-China.com

    Get Price
  • Vicat Test Apparatus - TESTMAK

    2021-7-2 · Home > Cement/Mortar > Vicat Apparatus Test > Needles for Vicat Needles for Vicat. H-3085.1 Plunger, Needle and Indicator, 300g. Vicat needle: Final Set, 1.13mm diameter. H-3070 Vicat needle: 1mm dia. 1mm dia. stainless steel with knurled threaded holder for H-3050

    Get Price
  • Vicat Needles - Humboldt Mfg

    2009-4-21 · Vicat Needle Apparatus Lab Equipment Medical & Lab Equipment For Sale Vicat Needle Apparatus Lab Equipment Medical & Lab Equipment: 279.7 ...

    Get Price
  • Vicat Needle Apparatus Lab Equipment Medical & Lab ...

    2017-8-8 · Standard Method of Test for Time of Setting of Hydraulic Cement by Vicat Needle AASHTO Designation: T 131-06 ASTM Designation: C 191-04a 1. SCOPE 1.1. These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually

    Get Price
  • T 131-06 - Time of Setting of Hydraulic Cement by Vicat Needle

    2018-12-22 · Followings are the apparatus used in setting time test of cement paste: 01. Vicat Apparatus: The Vicat apparatus shall consist of. Vicat apparatus consists a frame has a movable rod with a platform at one end and the needle which can be attached at the other end. Needle: I) Needle for determining the initial setting time – The needle shall ...

    Get Price
  • Standard Vicat apparatus | Geo Lab Nemo – Supplier ...

    The Vicat frame consists essentially of a metal stand with a sliding rod. An adjustable indicator moves over a graduated scale. The needle or plunger is attached to the bottom end of the rod to make up the test weight of 300 g. The frame 63-L0028/1 is supplied without accessories, which have to be ordered separately depending on the requirement.

    Get Price
  • Standard Vicat Apparatus | Controls Group

    The Vicat frame consists essentially of a metal stand with a sliding rod. An adjustable indicator moves over a graduated scale. The needle or plunger is attached to the bottom end of the rod to make up the test weight of 300 g. The frame 63-L0028/1 is supplied without accessories, which have to be ordered separately depending on the requirement.

    Get Price
  • Standard Vicat Apparatus | Controls Group

    The Vicat Apparatus is designed for determining the normal consistency, standard consistency and time of setting of cement and lime in accordance with ASTM and AASHTO specifications. The apparatus consists of a frame bearing a movable plunger of 300 grams weight. The Plunger is 10 mm diameter at one end and is fitted with a removable 1 mm ...

    Get Price
  • Vicat Apparatus | ELE International

    2021-7-2 · Vicat Apparatus, Set Time & Consistency. Designed to switch between 17.5mm dia. plunger for consistency determinations and a 2mm dia. needle for time of set determinations. Plunger assembly with adjustable indicator weighs 400g with 17.5mm needle attached and 300g with 2mm needle. Includes graduated 0-50mm scale, frame with bakelite platform ...

    Get Price
  • Vicat Apparatus, Set Time & Consistency - Humboldt Mfg

    2021-7-2 · Computer-controlled Vicat needle apparatus with six (6) 2' x 3' test stations positioned in a rectangular water bath. The Computer-controlled, Vicat Apparatus can be used to determine the initial and final setting time of cement, mortar pastes and gypsum.

    Get Price
  • Vicat Apparatus, Computer Controlled - Humboldt Mfg

    2017-8-8 · Standard Method of Test for Time of Setting of Hydraulic Cement by Vicat Needle AASHTO Designation: T 131-06 ASTM Designation: C 191-04a 1. SCOPE 1.1. These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually

    Get Price
  • Vicat Test Sets - Setting Time & Consistency - Utest ...

    A H M 531 Cement consistency and Setting time By: Ahmed Essam Mansour Apparatus & Materials: 1. VICAT Apparatus. 2. Digital weighing scale, used to measure the weight of dry cement. 3. Glass graduates, used to measure the volume of water. 4. Trowel. 5. Mixing bowl. 6. Stop-watch. 7. Portland Pozzolan Cement.

    Get Price
  • Experiment No. 01

    2020-1-13 · Prepared By: Mr. Neeraj Mehta Page 3 Experiment No.3 Aim:- To determine initial and final setting time of a given cement by vicat apparatus. Apparatus:- Vicat apparatus and vicat plunger vicat needle, 4 mould, gauging trowel, measuring jar weighing balance, stop watch, rice plates, weight box rubber gloves & glass places.

    Get Price
  • China En 196-3 Standard Manual Cement Vicat Needle Test ...

    Vicat apparatus definition is - a device for determining the normal consistency and time of setting of portland cements that consists of a rod weighing 300 grams, having a needle in each end, and supported in a frame with a graduated scale to measure the distance to which the needle penetrates the cement.

    Get Price
  • Modified Vicat apparatus - PINZUAR

    2021-6-5 · To determine Initial and Final setting time of Cement. Apparatus: 1) Vicat Apparatus: A device used to determine Standard Consistency and Setting Times consists of rod weighing 300 grams, having a needle at one end and supported in the frame with Graduated scale for measuring the Penetration. Also having a mould to put the cement.

    Get Price
  • Vicat Apparatus | Definition of Vicat Apparatus by Merriam ...

    PC-controlled Vicat needle apparatus, 8 points. in a rectangular trough. Tests must be performed in humidity air (>95%). final set time, as well as of setting plots. an additional 300 g ± 1 g. After each penetration. the Vicat needle is automatically cleaned. Dim. (W x D x H) = 700 x 600 x 600 mm.

    Get Price
  • Initial and Final Setting Time of Cement | Definition ...

    2018-3-5 · Standard Method of Test for. Time of Setting of Hydraulic Cement by Vicat Needle AASHTO Designation: T 131-06 ASTM Designation: C 191-04a 1. 1.1.. SCOPE These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated standard Vicat apparatus…

    Get Price
  • PC-controlled Vicat needle apparatus, 8 points - testing.de

    Designation: C 191 – 04a American Association State Highway and Transportation Officials Standard AASHTO No.: T131 Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle 1 This standard is issued under the fixed designation C 191; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last …

    Get Price
  • Setting Time - Vicat Needle ASTM C 191 | Cement | Time

    Vicat Needle Apparatus. Used to determine the amount of water required to produce a cement paste of standard consistency and the setting time. The time it takes for a cement to stiffen to a standard value after addition of water is commonly known as the set time. The test involves mixing cement with water and then measuring its resistance to ...

    Get Price
  • LAB 2 Setting time C191-04a.pdf - American Association ...

    2015-1-1 · T 131-2015,These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given: Method A is the Reference Test Method using the manually operated standard Vicat [email protected] while Method B permits the use of an automatic Vicat machine that [email protected] in accordance with the qualification requirements of this …

    Get Price
  • Standard Vicat apparatus | Geo-Con Products

    Manual Vicat needle. Consisting of a base with support, a sliding probe measuring Ø 10 m and weighing 300 g, and a graduated scale. Supplied complete with a Ø 1.13 mm needle for initial setting and a Ø 1.13 mm needle for final setting, a Ø 120 mm glass base and a tapered mold measuring (EN) Ø 70/80 x 40 mm. Molding tank

    Get Price
  • Vicat needle – Testlab

    2020-1-13 · Prepared By: Mr. Neeraj Mehta Page 3 Experiment No.3 Aim:- To determine initial and final setting time of a given cement by vicat apparatus. Apparatus:- Vicat apparatus and vicat plunger vicat needle, 4 mould, gauging trowel, measuring jar weighing balance, stop watch, rice plates, weight box rubber gloves & glass places.

    Get Price
  • Experiment No. 01

    2021-6-3 · Vicat apparatus with Vicat plunger, Vicat mould, Glass plate, Measuring jar, Weighing scale, Trowel etc. Description Initial Setting Time is the time elapsed between the moment the water is added to the cement sample and the time at which the cement paste starts losing plasticity.

    Get Price
  • SOLVE - ms-nitk.vlabs.ac.in

    Tests must be performed in humidity air (>95%) The unit automatically records initinal set time. and final set time, as well as of setting plots. Weight of plunger and the Vicat needle are. an additional 300 g ± 1 g. After each penetration the Vicat needle is. automatically cleaned. Scope of delivery.

    Get Price
  • PC-controlled Vicat needle apparatus, 6 points - testing.de

    2020-1-10 · STANDARD CONSISTENCY AND SETTING TIMES TEST OF CEMENT. OBJECTIVE: To determine: i) Standard Consistency ii) Initial and final setting times of a cement sample. APPARATUS REQUIRED: 1) Vicat apparatus with Vicat Plunger (10±0.05mm diameter) 2) Vicat needle ( c/s area 1mm2 with flat end needle for initial setting time and circular, c/s area 1mm2 ...

    Get Price
  • STANDARD CONSISTENCY AND SETTING TIMES TEST OF

    2019-7-30 · 4) Place the mould just below Vicat needle apparatus & keep 1 mm square needle in exact position.Now release the moving rod and note the reading . Now raise the moving rod & clear off all the cement paste and wipe off the needle clear. 5) Repeat the step no:4 above at regular interval of ½ minute till the reading becomes 5 mm exactly.

    Get Price
  • Standard Consistency Test of Cement - GharPedia

    Procedure for Standard Consistency of Cement. Keep the vicat apparatus on a level base (when using vicat apparatus with dashpot, keep the bearing movable rod to its highest position and pin it.) Unscrew the top of the dashpot. Half fill the dashpot with any suitable oil of viscosity and screw the top. Work the plunger a number of times.

    Get Price
  • INITIAL SETTING TIME AND FINAL SETTING TIME OF

    2018-12-30 · 5 Department of Civil Engineering, MUST Related Theory: Vicat Apparatus: A device for determining the normal consistency and time of setting of Portland cements that consists of a rod weighing 300 grams, having a needle in each end, and supported in a frame with a graduated scale to measure the distance to which the needle penetrates through ...

    Get Price
  • Standard Vicat apparatus | Geo-Con Products

    The Vicat Test Apparatus is used to determine the amount of water required to produce a cement paste of standard consistency and the setting time. The frame is supplied complete with a 300 g consistency plunger (dia. 10 mm). The measurement of the movement is given by an indicator which moves along a scale graduated in millimetres.

    Get Price
  • Vicat test apparatus – PROFIX6 MATERIAL TESTING

    2018-11-14 · The Vicat apparatus shall consist of a frame D having a movable rod B with a platform A at one end and the following which can be attached at the other end: . 4 b) d Needle C for determining the initial setting time, Needle Ffor determining the final setting time, and Plunger G for determining the standard

    Get Price
  • IS 5513 (1996): Specification for vicat apparatus

    Find Vicat Apparatus manufacturers, Vicat Apparatus suppliers, exporters, wholesalers and distributors in Maharashtra India - List of Vicat Apparatus selling companies from Maharashtra with catalogs, phone numbers, addresses & prices for Vicat Apparatus.

    Get Price
  • Vicat Apparatus in Maharashtra - Manufacturers and ...

    2021-6-3 · Vicat apparatus with Vicat plunger, Vicat mould, Glass plate, Measuring jar, Weighing scale, Trowel etc. Description Initial Setting Time is the time elapsed between the moment the water is added to the cement sample and the time at which the cement paste starts losing plasticity.

    Get Price
  • SOLVE - ms-nitk.vlabs.ac.in

    2009-4-21 · Vicat Needle Apparatus Lab Equipment Medical & Lab Equipment For Sale Vicat Needle Apparatus Lab Equipment Medical & Lab Equipment: 279.7 ...

    Get Price
  • Standard Consistency Test of Cement - GharPedia

    2020-1-10 · STANDARD CONSISTENCY AND SETTING TIMES TEST OF CEMENT. OBJECTIVE: To determine: i) Standard Consistency ii) Initial and final setting times of a cement sample. APPARATUS REQUIRED: 1) Vicat apparatus with Vicat Plunger (10±0.05mm diameter) 2) Vicat needle ( c/s area 1mm2 with flat end needle for initial setting time and circular, c/s area 1mm2 ...

    Get Price
  • Vicat Needle Apparatus Lab Equipment Medical & Lab ...

    This test method covers the determination of the time of setting of hydraulic cement by means of the Vicat needle. Equipment Vicat apparatus – Consists of a frame, a movable rod weighing 300 g with a 10 mm plunger on one end and a 1 mm removable needle on the other end. - For normal consistency test of standard paste we use a plunger with 10mm diameter.

    Get Price
  • STANDARD CONSISTENCY AND SETTING TIMES TEST OF

    2021-7-4 · Place cement paste on the ring of the Vicat apparatus and remove the excess cement paste with the help of the trowel. Make the plunger end with the surface of the past and tight the set screw. Set movable indicator to upper zero marks of the scale or initial reading could be taken. Then release the rod immediately.

    Get Price
  • Standard Vicat apparatus - servereal.com

    The standard Vicat apparatus is used to test the water consumption needs for standard cement consistence and the setting time. 2. Specification. Sliding part weight: 300±1g. Sliding part max travel:70mm. Consistence test rod diameter: φ10±0.05mm. Test needle diameter: φ1.13±0.05mm. Overall size(L*W*H): 170×110×300mm. Net weight: approx 3.8kg

    Get Price
  • Vicat test apparatus – PROFIX6 MATERIAL TESTING

    The Vicat Test Apparatus is used to determine the amount of water required to produce a cement paste of standard consistency and the setting time. The frame is supplied complete with a 300 g consistency plunger (dia. 10 mm). The measurement of the movement is given by an indicator which moves along a scale graduated in millimetres.

    Get Price
  • Vicat needle – Testlab

    Find Vicat Apparatus manufacturers, Vicat Apparatus suppliers, exporters, wholesalers and distributors in Maharashtra India - List of Vicat Apparatus selling companies from Maharashtra with catalogs, phone numbers, addresses & prices for Vicat Apparatus.

    Get Price
  • Vicat Apparatus in Maharashtra - Manufacturers and ...

    2017-8-8 · 12.1 Report the time of setting and the method used as follows: Vicat time of setting (Aor B) _____ min Vical final time of setting (Aor B) _____ min Method A—Manual Vicat Needle Apparatus 13. Manual Vicat Apparatus 13.1 The Vicat apparatus shall consist of a frame, A, Fig. A1.1, bearing a movable rod, B, weighing 300 g, one end, C,

    Get Price
  • Standard Test Method for Time of Setting of Hydraulic ...

    特 價 專 區 透地雷達GPR 土木、建築、瀝青鋪面、大地工程試驗 非破壞檢測儀器 道路交通標誌標線測試儀器 雷射測量儀 ...

    Get Price
  • Standard Vicat apparatus--YENSTRON CORP.

    2015-1-1 · T 131-2015,These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given: Method A is the Reference Test Method using the manually operated standard Vicat [email protected] while Method ...

    Get Price
  • IS 4031-5 (1988): Methods of physical tests for hydraulic ...

    2018-2-2 · setting time. 5.3 Determination of Final Setting Time — Replace the needle (C) of the Vicat apparatus by the needle with an annular attachment (F). The cement shall be considered as finally set when, upon applying the needle gently to the surface of the test block, the needle makes an impression thereon, while the attachment fails to do so.

    Get Price
  • Various Tests On Cement - Expert Civil

    The needle with the annular collar is attached to the moving rod of the Vicat apparatus. The needle is gently released. The time at which the needle makes an impression on test block and the collar fails to do so is noted. Final setting time is the difference between the time at which water was added to cement and time as recorded in the ...

    Get Price
  • Suman Engineering Works, Delhi, Moulds

    2012-4-19 · Manufacturers, Exporters and Suppliers of qualitative assortment of Molds and Apparatus. These products are developed by us in standard as well as customized s…

    Get Price